Ultra-Thin High Frequency Transformer LED Lighting - China Factory Supplier for Electronic Step-Up Transformers
- Home appliance power supply, industrial and communication equipment power supply, printer, copier power supply and emerging medical equipment, small power supply, network communication power supply, 5G network communication products, bathroom products, refrigerators, washing machines and other home appliances.
- The length and width can be 4mm, the duty cycle is small, can be customized according to specifications, and the power can more than 60W.
A. Determine the parameters of BOBBIN
B. The principle for all wire wrapping is to ensure flatness and non-overlapping
C. For single-group wiring, a single-colored wire is sufficient. For double-group wiring, use double-colored wires or open wires immersed in tin to distinguish the pins, to avoid wiring errors
D. The crossing line must be isolated with tape
- The sparse winding is completely evenly spaced
- The closely wound wires are evenly and tightly arranged
- Both sides of the coil should maintain a sufficient safety distance A and B from the edges of the winding slot
- The length of the sleeve must be sufficient, with one end extending into the safety tape of the winding tube and the other end extending beyond the upper edge of the BOBBIN, but must not be close to the PIN
- The outermost tape is cut on the core assembly surface, and the cut area must be covered by the core
- The edge of the tape should be flush with the winding groove, and the tape should not be skewed, folded back, or damaged
- Tape must be applied under the crossover wire to maintain insulation between the crossover wire and the underlying coil
A. Vertical BOBBIN:
Thick wire (above 0.8φ): wrap once. Fine wire (0.2–0.8φ): wrap 1.5 times. Extremely thin wire (below 0.2φ): wrap 2–3 times. Principle: Wind as tightly as possible without exceeding the protruding points.
B. Horizontal BOBBIN: Wrap approximately 2–3 turns. Do not press the sparse winding down to the bottom to avoid burning the BOBBIN during soldering. This method is only used when there are width constraints and strict specifications. Press the winding down to the bottom after soldering, then trim the PIN to reduce the overall width of the transformer.
C. Horizontal type winding: Wind loosely for about 2–3 turns. Do not press down to the bottom to avoid burning the BOBBIN during soldering.
Note: If the product has a width limitation and the specifications are tight, the wire-wrapping must be pressed down as much as possible.
General rules for casing location:
A. Externally: The shorter the distance between the end of the sleeve and the PIN, the better. However, it is absolutely forbidden to wrap the sleeve around the PIN, as this will cause a solder bridge.
B. Internal: A seamless wall fit, flush with the BOBBIN for approximately 1/2L in length.
The width and material of margin tape cannot be arbitrarily changed, as they are subject to safety regulations. The width of the tape for the false wall should generally equal the height of the winding coil to prevent copper wires from overlapping on the false wall during winding.
Tips: When thick conduits affect the thickness of incoming and outgoing lines, skip the outgoing lines and pay special attention to the position of the conduit, ensuring a sufficient safety distance.
- A. A circle of unconnected leads, with no short circuit between the ends, separated by insulating material
- B. For connecting wires in a circle, the width of the tape must be greater than that of the copper sheet
- C. Two leads of copper sheets with more than one turn
- D. Copper sheet of intermediate drawn type, with three leads
1) Vertical cable management standard:
- Both thin and thick wires need to be neatly wound for more than one full turn, at 2/3 of the height between the base and the boss
- The length of the wire end must not exceed half the distance between two adjacent feet, and the maximum length must not exceed 1mm
- Multiple sets of wires are wound together; thin wires on the top layer
- If there is a casing, the length of the casing should not be shorter than the base
- Different footprints within the same slot should be wound in the same direction
2) Horizontal cable management standard:
- The thread should be evenly distributed on the foot, extending at least half the length of the thread foot
- The thread should be wound spirally upwards from the heel, covering at least one full circle
- The wire end must not exceed half the distance between two adjacent pins, maximum 1mm
- Multiple sets of wires wound together, thin wires on top layer
- Sleeve length should not be shorter than the base and must not be close to the PIN
- After soldering, the PIN legs should be flat and smooth, without any foreign objects adhering to them
- The thread end should not be higher than the bump
- After soldering, the BOBBIN should be intact, with no damage or short pins
- There is minimal residue of soldering flux, with no tin staining or short circuits
- The adhesive tape shows no damage
- The solder should cover at least one full circle
- After soldering, there should be no lateral solder spikes
- The iron core assembly surface should be flat and free from any tilt
- The bobbin, core, and wiring pins should be kept clean and free from any impurities or adhesive
- Identify the direction in which the CORE with GAP should be placed
- The maximum skew of CORE of EE, EI, and UU types must not exceed 0.5mm or 1/10 of the CORE width