High Frequency Transformer LED Lighting - Step Up Electronic Transformer from China Suppliers & Factory
Home appliance power supply, industrial and communication equipment power supply, printer, copier power supply and emerging medical equipment, small power supply, network communication power supply, 5G network communication products, bathroom products, refrigerators, washing machines and other home appliances.
One of the key points in the manufacturing process of high-frequency transformers:
winding
A. Determine the parameters of BOBBIN
B. The principle for all wire wrapping is to ensure flatness and non-overlapping
C. For single-group wiring, a single-colored wire is sufficient. For double-group wiring, it is necessary to use double-colored wires or open wires immersed in tin to distinguish the pins, to avoid wiring errors
D. The crossing line must be isolated with tape
1. The sparse winding is completely evenly spaced
2. The closely wound wires are evenly and tightly arranged
3. Both sides of the coil should maintain a sufficient safety distance A and B from the edges of the winding slot
4. The length of the sleeve must be sufficient, with one end extending into the safety tape of the winding tube and the other end extending beyond the upper edge of the BOBBIN, but must not be close to the PIN
5. The outermost tape is cut on the core assembly surface, and the cut area must be covered by the core.
6. The edge of the tape should be flush with the winding groove, and the tape should not be skewed, folded back, or damaged.
7. Tape must be applied under the crossover wire to maintain insulation between the crossover wire and the underlying coil.
The second key point of the manufacturing process of high-frequency transformers.
thread winding
A vertical BOBBIN
Thick wire: wrap the wire once for diameters above 0.8φ
Fine wire 0.2-0.8φ, wrapped 1.5 times
Wrap the wire 2-3 times for extremely thin wire with diameter below 0.2φ
Principle of vertical BOBBIN winding: The wire should be wound as tightly as possible without exceeding the protruding points.
B Horizontal BOBBIN: Wrap approximately 2-3 turns, do not press the sparse winding down to the bottom to avoid burning the BOBBIN during soldering. This method is only used when there are width constraints and strict specifications. Press the winding down to the bottom after soldering, then trim the PIN to reduce the overall width of the transformer.
C Horizontal (Horizontal type, winding method for BOBBIN: wind loosely for about 2-3 turns, do not press down to the bottom to avoid burning the BOBBIN during soldering.
Note: If the product has a width limitation and the specifications are tight, it is a special case where the wire-wrapping part must be cut short. In this case, the wire-wrapping must be pressed down as much as possible.
Key points of manufacturing process for high-frequency transformers (Part 3):
casing
General rules for the location of casing:
A. Externally: The shorter the distance between the end of the sleeve and the PIN, the better. However, it is absolutely forbidden to wrap the sleeve around the PIN, as this will cause a solder bridge.
B Internal: a seamless wall fit, flush with the BOBBIN for approximately 1/2L in length.
With the cooperation of the side wall, the casing must be positioned within the retaining wall.
The width and material of margin tape cannot be arbitrarily changed, as they are subject to safety regulations and require special attention during transformer design.
The width of the tape for the false wall: Generally, it should be equal to the height of the winding coil to prevent copper wires from overlapping on the false wall during winding. However, if it is difficult to install the core, the tape may sometimes be wrapped around about 1/2 to 3/4 of the height, but the principle is to ensure that the winding does not overlap on the false wall.
Tips: Sometimes, when the thickness of the incoming and outgoing lines is affected due to the presence of thick conduits, it is advisable to skip the outgoing lines. In this case, special attention should be paid to the position of the conduit, ensuring a sufficient safety distance (the width of the depth into the false wall).
This point must be penetrated deep into the false wall. Sometimes, due to large gaps in the false wall or when copper foil is wound around M/F, it is not obvious whether it has penetrated deep into the false wall or the M/T on the line. In such cases, it is necessary to use a safety rod with the same width as the M/T and measure each one.
Key points of manufacturing process for high-frequency transformers (Part 4):
The winding principles of copper sheets generally include the following methods:
A. A circle of unconnected leads, with no short circuit between the ends, and separated by insulating material
B. For connecting wires in a circle, the width of the tape must be greater than that of the copper sheet
C. Two leads of copper sheets with more than one turn
D. Copper sheet of intermediate drawn type, with three leads
Key points of manufacturing process for high-frequency transformers (Part 5):
Cable management
1) Vertical cable management standard
Both thin and thick wires need to be neatly wound for more than one full turn, with the winding position located at 2/3 of the height between the base and the boss (if insufficient, increase the number of winding turns)
The length of the B-wire end must not exceed half the distance between two adjacent feet, and the maximum length must not exceed 1mm.
Multiple sets of wires are wound together and organized. The thin wires should be placed on the top layer, and it is not allowed to organize one strand before moving on to the next.
If there is a casing, the length of the casing should not be shorter than the base
When dealing with different footprints within the same slot, they should be wound in the same direction.
2) Horizontal cable management standard
The thread should be evenly distributed on the foot, with the thread end extending at least half of the length of the thread foot (if it is insufficient, increase the number of thread loops to make up for it, but it cannot exceed the length of the thread foot at most)
B. The thread should be wound spirally upwards from the heel and should cover at least one full circle.
The length of the C-wire end must not exceed half the distance between two adjacent pins, and the maximum length must not exceed 1mm.
D. Multiple sets of wires should be wound and organized together, with thin wires placed on the top layer. It is not allowed to organize one strand before moving on to the next.
When routing wires in the same slot but different pins, they can be wound in the same direction, and the length of the sleeve should not be shorter than the base, and it should not be close to the PIN.
Key points of manufacturing process for high-frequency transformers (Part 6):
soldering
1) After soldering, the PIN legs should be flat and smooth, without any foreign objects adhering to them.
2) The thread end should not be higher than the bump.
3) After soldering, the BOBBIN should be intact, with no damage or short pins.
4) There is minimal residue of soldering flux, with no tin staining or short circuits.
5) The adhesive tape shows no damage.
6) The solder should cover at least one full circle.
7) After soldering, there should be no lateral solder spikes.
Key points of manufacturing process for high-frequency transformers (Part 7):
combination
1) The iron core assembly surface should be flat and free from any tilt.
2) The bobbin, core, and wiring pins should be kept clean and free from any impurities or adhesive.
3) Identify the direction in which the CORE with GAP should be placed.