Introducing our advanced flat ferrite core, specifically designed for ultra-thin switch mode power supplies. This innovative component meets the high-power demands of power transformers while maintaining an ultra-slim profile. As a leading factory and reliable suppliers in China, we ensure that our products are engineered for efficiency and performance. Upgrade your power solutions with our state-of-the-art ferrite core, perfect for modern applications
  • Model: EE
  • Operating Frequency: 20kHz to 500kHz
  • Output Power: 8 to 25 W
  • Output Voltage: 0.5v-15000v
  • Output Current: -40℃ to +125℃
  • Storage Temperature: -40℃ to +125℃
  • Operating Temperature: -40℃ to +125℃
  • Storage Humidity: 30 to 95%

Application
  • Home appliance power supply, industrial and communication equipment power supply, printer, copier power supply and emerging medical equipment, small power supply, network communication power supply, 5G network communication products, bathroom products, refrigerators, washing machines and other home appliances.
Features
⚡ The length and width can be 4mm, the duty cycle is small, can be customized according to specifications, and the power can more than 60W.
More Detailed Information

Key Point 1 — Winding

A. Determine the parameters of BOBBIN
B. The principle for all wire wrapping is to ensure flatness and non-overlapping
C. For single-group wiring, a single-colored wire is sufficient. For double-group wiring, use double-colored wires or open wires immersed in tin to distinguish pins, to avoid wiring errors
D. The crossing line must be isolated with tape

1. The sparse winding is completely evenly spaced
2. The closely wound wires are evenly and tightly arranged
3. Both sides of the coil should maintain a sufficient safety distance A and B from the edges of the winding slot
4. The length of the sleeve must be sufficient, with one end extending into the safety tape of the winding tube and the other end extending beyond the upper edge of the BOBBIN, but must not be close to the PIN
5. The outermost tape is cut on the core assembly surface, and the cut area must be covered by the core
6. The edge of the tape should be flush with the winding groove, and the tape should not be skewed, folded back, or damaged
7. Tape must be applied under the crossover wire to maintain insulation between the crossover wire and the underlying coil

Key Point 2 — Thread Winding

A Vertical BOBBIN
Thick wire: wrap the wire once for diameters above 0.8φ
Fine wire 0.2–0.8φ, wrapped 1.5 times
Wrap the wire 2–3 times for extremely thin wire with diameter below 0.2φ
Principle: The wire should be wound as tightly as possible without exceeding the protruding points.

B Horizontal BOBBIN: Wrap approximately 2–3 turns, do not press the sparse winding down to the bottom to avoid burning the BOBBIN during soldering.
C Horizontal type: wind loosely for about 2–3 turns, do not press down to the bottom to avoid burning the BOBBIN during soldering.
Note: If the product has a width limitation and the specifications are tight, the wire-wrapping part must be cut short and pressed down as much as possible.

Key Point 3 — Casing

A. Externally: The shorter the distance between the end of the sleeve and the PIN, the better. It is absolutely forbidden to wrap the sleeve around the PIN, as this will cause a solder bridge.
B. Internal: a seamless wall fit, flush with the BOBBIN for approximately 1/2L in length.
The width and material of margin tape cannot be arbitrarily changed, as they are subject to safety regulations.
The width of the tape for the false wall should generally equal the height of the winding coil to prevent copper wires from overlapping on the false wall during winding.

Key Point 4 — Copper Sheet Winding Principles

A. A circle of unconnected leads, with no short circuit between the ends, and separated by insulating material
B. For connecting wires in a circle, the width of the tape must be greater than that of the copper sheet
C. Two leads of copper sheets with more than one turn
D. Copper sheet of intermediate drawn type, with three leads

Key Point 5 — Cable Management

1) Vertical cable management standard:
Both thin and thick wires need to be neatly wound for more than one full turn, with the winding position at 2/3 of the height between the base and the boss.
The B-wire end must not exceed half the distance between two adjacent feet, max 1mm.
Multiple sets of wires are wound together; thin wires on the top layer.

2) Horizontal cable management standard:
The thread should be evenly distributed on the foot, extending at least half the length of the thread foot.
The thread should be wound spirally upwards from the heel, covering at least one full circle.
The C-wire end must not exceed half the distance between two adjacent pins, max 1mm.
Multiple sets of wires wound together, thin wires on top layer. Sleeve length should not be shorter than the base.

Key Point 6 — Soldering

1) After soldering, PIN legs should be flat and smooth, without any foreign objects.
2) The thread end should not be higher than the bump.
3) After soldering, the BOBBIN should be intact, with no damage or short pins.
4) Minimal residue of soldering flux, no tin staining or short circuits.
5) The adhesive tape shows no damage.
6) The solder should cover at least one full circle.
7) After soldering, there should be no lateral solder spikes.

Key Point 7 — Assembly / Combination

1) The iron core assembly surface should be flat and free from any tilt.
2) The bobbin, core, and wiring pins should be kept clean and free from any impurities or adhesive.
3) Identify the direction in which the CORE with GAP should be placed.
4) The maximum skew of CORE of EE, EI, and UU types must not exceed 0.5mm or 1/10 of the CORE width.

Product Details Image
High Frequency Transformer LED Lighting Step up Electronic Transformer 2
High Frequency Transformer LED Lighting Step up Electronic Transformer 1
High Frequency Transformer LED Lighting Step up Electronic Transformer 1
Make a Free Consultation

Your Name*

E-mail*

Product Name

Company Name

Phone Number

Country

Remarks

Frequently Asked Questions
Q What are the main applications of high-frequency transformers? +
High-frequency transformers are widely used in home appliance power supplies, industrial and communication equipment, printers, copiers, medical equipment, network communication power supplies, 5G products, bathroom appliances, refrigerators, and washing machines.
Q What are the key specifications of this high-frequency transformer? +
The transformer features a compact design with length and width of 4mm, a small duty cycle, customizable specifications, and a power output capability exceeding 60W.
Q What winding principles must be followed during manufacturing? +
All wire wrapping must ensure flatness and non-overlapping. For double-group wiring, double-colored or distinguishable wires are required. Crossing lines must be isolated with tape, and coil edges must maintain a sufficient safety distance from the winding slot edges.
Q What are the soldering quality standards for high-frequency transformers? +
After soldering, PIN legs must be flat and smooth with no foreign objects. The solder must cover at least one full circle, with minimal flux residue, no tin staining, no short circuits, no lateral solder spikes, and the BOBBIN must remain intact without damage.
Q Can the transformer be customized according to specific requirements? +
Yes, the high-frequency transformer can be customized according to customer specifications. You can submit your requirements through our free consultation form, including product details such as size, power, and application environment.
Q What are the core assembly requirements for high-frequency transformers? +
The iron core assembly surface must be flat and free from any tilt. The bobbin, core, and wiring pins must be kept clean and free from impurities or adhesive. The GAP direction of the CORE must be correctly identified, and the maximum skew for EE, EI, and UU type cores must not exceed 0.5mm or 1/10 of the CORE width.