Leave Your Message
High Frequency Transformer LED Lighting Step-Up Electronic Transformer from China Suppliers and Factory
Hot Products
Products Categories
Featured Products

High Frequency Transformer LED Lighting Step-Up Electronic Transformer from China Suppliers and Factory

Introducing our innovative ultra-thin switch mode power supply, designed specifically for optimal adaptability. Featuring a flat ferrite core, this product not only meets the high-power demands of power transformers but also adheres to the ultra-thin volume requirements crucial in today’s technology landscape. As a leading factory in China, we are committed to providing top-quality solutions. Trust our expert suppliers to deliver cutting-edge products that enhance your power supply systems efficiently
  • Model: EE
  • Operating Frequency: 20kHz to 500kHz
  • Output Power: 8 to 25 W
  • Output Voltage: 0.5v-15000v
  • Output Current: -40℃ to +125℃
  • Storage Temperature: -40℃ to +125℃
  • Operating Temperature: -40℃ to +125℃
  • Storage Humidity: 30 to 95%

Application
  • Home appliance power supply, industrial and communication equipment power supply, printer, copier power supply and emerging medical equipment, small power supply, network communication power supply, 5G network communication products, bathroom products, refrigerators, washing machines and other home appliances.
Features
  • The length and width can be 4mm, the duty cycle is small, can be customized according to specifications, and the power can more than 60W.
More Detailed Information
High-Frequency Transformer — Manufacturing Process Details

Key Point 1: Winding
A. Determine the parameters of BOBBIN
B. The principle for all wire wrapping is to ensure flatness and non-overlapping
C. For single-group wiring, a single-colored wire is sufficient. For double-group wiring, it is necessary to use double-colored wires or open wires immersed in tin to distinguish the pins, to avoid wiring errors
D. The crossing line must be isolated with tape
1. The sparse winding is completely evenly spaced
2. The closely wound wires are evenly and tightly arranged
3. Both sides of the coil should maintain a sufficient safety distance A and B from the edges of the winding slot
4. The length of the sleeve must be sufficient, with one end extending into the safety tape of the winding tube and the other end extending beyond the upper edge of the BOBBIN, but must not be close to the PIN
5. The outermost tape is cut on the core assembly surface, and the cut area must be covered by the core.
6. The edge of the tape should be flush with the winding groove, and the tape should not be skewed, folded back, or damaged.
7. Tape must be applied under the crossover wire to maintain insulation between the crossover wire and the underlying coil.

Key Point 2: Thread Winding
A Vertical BOBBIN
Thick wire: wrap the wire once for diameters above 0.8φ
Fine wire 0.2–0.8φ, wrapped 1.5 times
Wrap the wire 2–3 times for extremely thin wire with diameter below 0.2φ
Principle of vertical BOBBIN winding: The wire should be wound as tightly as possible without exceeding the protruding points.
B Horizontal BOBBIN: Wrap approximately 2–3 turns, do not press the sparse winding down to the bottom to avoid burning the BOBBIN during soldering.
C Horizontal type: wind loosely for about 2–3 turns, do not press down to the bottom to avoid burning the BOBBIN during soldering.
Note: If the product has a width limitation and the specifications are tight, it is a special case where the wire-wrapping part must be cut short. In this case, the wire-wrapping must be pressed down as much as possible.

Key Point 3: Casing
General rules for the location of casing:
A. Externally: The shorter the distance between the end of the sleeve and the PIN, the better. However, it is absolutely forbidden to wrap the sleeve around the PIN, as this will cause a solder bridge.
B. Internal: a seamless wall fit, flush with the BOBBIN for approximately 1/2L in length.
The width and material of margin tape cannot be arbitrarily changed, as they are subject to safety regulations and require special attention during transformer design.
The width of the tape for the false wall should generally be equal to the height of the winding coil to prevent copper wires from overlapping on the false wall during winding.

Key Point 4: Winding Principles of Copper Sheets
A. A circle of unconnected leads, with no short circuit between the ends, and separated by insulating material
B. For connecting wires in a circle, the width of the tape must be greater than that of the copper sheet
C. Two leads of copper sheets with more than one turn
D. Copper sheet of intermediate drawn type, with three leads

Key Point 5: Cable Management
1) Vertical cable management standard:
Both thin and thick wires need to be neatly wound for more than one full turn, with the winding position located at 2/3 of the height between the base and the boss.
The length of the B-wire end must not exceed half the distance between two adjacent feet, and the maximum length must not exceed 1mm.
Multiple sets of wires are wound together and organized. The thin wires should be placed on the top layer.
2) Horizontal cable management standard:
The thread should be evenly distributed on the foot, with the thread end extending at least half of the length of the thread foot.
The thread should be wound spirally upwards from the heel and should cover at least one full circle.
Multiple sets of wires should be wound and organized together, with thin wires placed on the top layer.

Key Point 6: Soldering
1) After soldering, the PIN legs should be flat and smooth, without any foreign objects adhering to them.
2) The thread end should not be higher than the bump.
3) After soldering, the BOBBIN should be intact, with no damage or short pins.
4) There is minimal residue of soldering flux, with no tin staining or short circuits.
5) The adhesive tape shows no damage.
6) The solder should cover at least one full circle.
7) After soldering, there should be no lateral solder spikes.

Key Point 7: Combination
1) The iron core assembly surface should be flat and free from any tilt.
2) The bobbin, core, and wiring pins should be kept clean and free from any impurities or adhesive.
3) Identify the direction in which the CORE with GAP should be placed.
4) The maximum skew of CORE of EE, EI, and UU types must not exceed 0.5mm or 1/10 of the CORE width.

Product Details Image
High Frequency Transformer LED Lighting Step up Electronic Transformer 2
High Frequency Transformer LED Lighting Step up Electronic Transformer 1
High Frequency Transformer LED Lighting Step up Electronic Transformer 1
Make a Free Consultation
Frequently Asked Questions (FAQ)
  • Q What are the main applications of this high-frequency transformer? +
    This high-frequency transformer is widely used in home appliance power supplies, industrial and communication equipment, printers, copiers, medical equipment, small power supplies, network communication, 5G products, bathroom products, refrigerators, and washing machines.
  • Q What are the key specifications of this transformer? +
    The length and width can be as small as 4mm, the duty cycle is small, and the power output can exceed 60W. The product can be customized according to specific specifications and requirements.
  • Q Can the transformer be customized to meet specific requirements? +
    Yes, the transformer can be fully customized according to your specifications. Parameters such as dimensions, power output, winding configuration, and BOBBIN type can be adjusted to meet your specific application needs.
  • Q What quality standards are followed during the manufacturing process? +
    The manufacturing process follows strict quality control across all stages including winding, thread winding, casing, copper sheet winding, cable management, soldering, and core combination. Key standards include flatness of winding, proper insulation, no solder bridges, and core skew within 0.5mm or 1/10 of the CORE width.
  • Q What types of CORE configurations are supported? +
    The transformer supports multiple core types including EE, EI, and UU configurations. The maximum allowable skew for these core types must not exceed 0.5mm or 1/10 of the CORE width to ensure optimal performance and safety.
  • Q How can I request a quote or consultation for this product? +
    You can submit a free consultation request using the inquiry form above. Please provide details such as your product name, company, phone number, country, and any specific requirements (size, color, materials, etc.) to receive an accurate and timely quote from our team.